WhisperKool 3500tiR Manuel du propriétaire

Naviguer en ligne ou télécharger Manuel du propriétaire pour Non WhisperKool 3500tiR. WhisperKool 3500tiR Owner`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 50
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
EXti 033114
WhisperKOOL EXTREME
OWNER’S MANUAL
The Coolest Thing In Wine Storage
Vue de la page 0
1 2 3 4 5 6 ... 49 50

Résumé du contenu

Page 1 - OWNER’S MANUAL

EXti 033114WhisperKOOL EXTREMEOWNER’S MANUALThe Coolest Thing In Wine Storage

Page 2

EXti 033114Page 8 | 1-800-343-9463QUICK START GUIDE This guide is meant to serve as a quick reference for installation of the WhisperKOOL unit. The re

Page 3 - TABLE OF CONTENTS

www.whisperkool.com | Page 9The performance and life of your WhisperKOOL unit is contingent upon the steps you take in preparing the wine cellar. Note

Page 4 - QUICK REFERENCE GUIDE

EXti 033114Page 10 | 1-800-343-9463Unobstructed AirowUnobstructed airflow to and from the unit is critical for the unit’s overall performance and lif

Page 5

www.whisperkool.com | Page 11Ambient Temperature FactorThe cooling unit has the ability to cool a wine cellar eciently to 55°F as long as the ambient

Page 6 - Remote Controller Layout

EXti 033114Page 12 | 1-800-343-9463TEST THE UNIT PRIOR TO INSTALLATION To prepare it for testing before installation in wall: • Unit needs to be in t

Page 7 - UNIT SPECIFICATIONS

www.whisperkool.com | Page 13REFER TO THE ACTIVE HUMIDITY INSTALLATION GUIDE FOR INSTRUCTIONS ON HOW TO INSTALL THE WATER LINE AND HUMIDISTAT.Minimum

Page 8 - INTRODUCTION

EXti 033114Page 14 | 1-800-343-9463PREPARING THE UNIT FOR INSTALLATIONApplying Insulation Tape Locate the (4) precut pieces of black foam tape include

Page 9

www.whisperkool.com | Page 15Exterior Grille Installation The exterior grille is required on all installations where the exhaust side of the unit is e

Page 10 - QUICK START GUIDE

EXti 033114Page 16 | 1-800-343-9463THROUGH-THE-WALL INSTALLATIONInstalling the UnitSlide the unit from the outside wall into your wine cellar with the

Page 11 - PREPARING THE WINE CELLAR

www.whisperkool.com | Page 17NOTES

Page 12 - Door and Door Seal

EXti 033114Copyright © 2012. WhisperKOOL. All rights reserved. WhisperKOOL copyrights this manual, the product design, and the design concepts, with a

Page 13 - 110ºF 55ºF

EXti 033114Page 18 | 1-800-343-9463ACTIVE HUMIDITY OPTION OVERVIEWUse of the Active Humidity OptionHumidity may uctuate in the wine cellar. The Activ

Page 14 - PRE-INSTALLATION

www.whisperkool.com | Page 19HUMIDISTAT INSTALLATIONFigure 2Figure 4Figure 3HUMIDISTAT INSTALLATIONScrewsTerminal BlockFigure 1Removing the Cover1. Mo

Page 15 - LINE AND HUMIDISTAT

EXti 033114Page 20 | 1-800-343-9463HUMIDISTAT INSTALLATIONFigure 5Wall AnchorsMounting With a Wall Mount Plate1. Make sure the humidistat is unplugge

Page 16 - Mounting Bracket

www.whisperkool.com | Page 21DUCTING OVERVIEWUse of DuctworkUse ductwork to connect the unit to the supply and return outlets in the wine cellar. Use

Page 17 - OPTIONAL EXTERIOR GRILLE

EXti 033114Page 22 | 1-800-343-9463Half Duct CongurationThere are a variety of ways to duct this unit, please review the dierent congurations to de

Page 18 - THROUGH-THE-WALL INSTALLATION

www.whisperkool.com | Page 23Fully DuctedAttic Mounted UnitDUCTING CONFIGURATIONSHeat ExhaustCold Air Supply-CellarCondenser IntakeReturn Air-Cellar S

Page 19

EXti 033114Page 24 | 1-800-343-9463STEP 1: Remove the lter grill from the unit by unscrewing the screws that hold it in place.STEP 2: Move the Duct

Page 20 - Figure 1

www.whisperkool.com | Page 25TMTMIf you have a unit with a remote controller (tiR), please review this section.The controller can be installed up to 5

Page 21 - HUMIDISTAT INSTALLATION

EXti 033114Page 26 | 1-800-343-9463RemoteControllerBottle ProbeCooling UnitBelow is an illustration of one possible way to congure the remote control

Page 22

www.whisperkool.com | Page 27Drain LineAll units come with a drain line for additional removal of excessive condensate. It is mandatory to install the

Page 23 - DUCTING OVERVIEW

www.whisperkool.com | Page 1TABLE OF CONTENTSQuick Reference GuideUnit ...Controller ...

Page 24 - DUCTING CONFIGURATIONS

EXti 033114Page 28 | 1-800-343-9463LIQUID MEASURING THERMOSTATThe WhisperKOOL Series cooling units come equipped with a liquid temperature measuring t

Page 25 - Return Air-Cellar Side

www.whisperkool.com | Page 29MULTI FAN SPEED CONTROLDesigned for wine cellars up to 1000 and 2000 cubic feet, the Extreme 3500ti/tiR, 5000ti/tiR and 8

Page 26 - STEP 3:

EXti 033114Page 30 | 1-800-343-9463Initial Start-UpWhen power is applied to the unit, the control will briey display all symbols, and the Compressor

Page 27

www.whisperkool.com | Page 31STANDARD CONTROLLER FUNCTIONSIf your unit is installed through the wall and does not have a remote keypad you will have t

Page 28 - Page 26

EXti 033114Page 32 | 1-800-343-9463SET 1. Press the “Set” button once and it will display the Set Point. After approximately 5 seconds, the display wi

Page 29 - DRAIN LINE

www.whisperkool.com | Page 33CPSM Mode Press the “Set” and the “Down Arrow” buttons simultaneously, for 10-15 seconds, and you will access the “Custom

Page 30 - LIQUID MEASURING THERMOSTAT

EXti 033114Page 34 | 1-800-343-9463STANDARD WIRE SCHEMATICCOMPNC C NO3 4 27 8 6109 1011 12!Max20A5 A16/608 A120V1 2 3 456 7 88 AEvap.LineFrontRecepta

Page 31 - MULTI FAN SPEED CONTROL

www.whisperkool.com | Page 35REMOTE CONTROLLER FUNCTIONSIf your unit has a remote keypad then you will have the Remote Controller.Button Normal Functi

Page 32 - Standard and Remote Controls

EXti 033114Page 36 | 1-800-343-9463Set 1. Press the “Set” button once and it will display the Set Point. After approximately 5 sec-onds, the display w

Page 33 - STANDARD CONTROLLER FUNCTIONS

www.whisperkool.com | Page 37CPSM Mode Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and you will access the “Customer

Page 34 - Alarm Codes

EXti 033114Page 2 | 1-800-343-9463QUICK REFERENCE GUIDEFront / Side ViewRear / Side ViewControllerBottle ProbeProbe InputGrille w/FilterControl Panel(

Page 35

EXti 033114Page 38 | 1-800-343-9463REMOTE WIRE SCHEMATICCOMPNC CNO34 27 8 610LineFrontReceptacleRearReceptacleCondFanEvapFanCompressor213546

Page 36 - STANDARD WIRE SCHEMATIC

www.whisperkool.com | Page 39MAINTENANCE SCHEDULEMonthly 1. Check lters2. Check for unusual noise or vibration3. Check the drain line to see if it is

Page 37 - REMOTE CONTROLLER FUNCTIONS

EXti 033114Page 40 | 1-800-343-9463TROUBLESHOOTING GUIDEUnit has ice forming on the evaporator Possible Cause Evaporator lter and/or coil are dirt

Page 38

www.whisperkool.com | Page 41TROUBLESHOOTING GUIDESolutionUnit should be level in wall to prevent leakingCheck drain line to make sure water can ow f

Page 39

EXti 033114Page 42 | 1-800-343-9463TECHNICAL ASSISTANCEWhisperKOOL Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. Pac

Page 40 - REMOTE WIRE SCHEMATIC

www.whisperkool.com | Page 43 Product Warranty InformationThe Coolest Thing In Wine StorageWhisperKOOL Product Terms and Conditions Including Product

Page 41 - MAINTENANCE SCHEDULE

EXti 033114Page 44 | 1-800-343-94637. This limited warranty is void if the factory applied serial number has been altered or removed from the Product

Page 42 - TROUBLESHOOTING GUIDE

www.whisperkool.com | Page 45in and out of buildings through doors, windows, vents, HVAC systems and anywhere else that air enters. Once it is discove

Page 43

EXti 033114Page 46 | 1-800-343-9463E. Correction of Errors and Inaccuracies: These Terms and Conditions may contain typographical errors or other err

Page 44 - ACCESSORIES FOR COOLING UNITS

www.whisperkool.com | Page 47NOTES

Page 45 - Product Warranty Information

www.whisperkool.com | Page 3QUICK REFERENCE GUIDERemote Front / Side ViewFully Ducted - Front / Side ViewRearController w/Remote BoxBottle ProbeGrille

Page 46 - Page 44

EXti 033114 WhisperKOOL1738 E. Alpine AveStockton, CA 952051-800-343-9463www.whisperkool.com

Page 47

EXti 033114Page 4 | 1-800-343-9463Evaporator and Condenser Fan••••ALARM Pre-Chill Display Control “ON/OFF” Buon•Turns the Cooling Unit “ON/OFF” 1An

Page 48 - Page 46

www.whisperkool.com | Page 5FAN SPEED REFERENCEUNIT SPECIFICATIONSYour fan speed selection will depend on the amount of heat that needs to be removed

Page 49

EXti 033114Page 6 | 1-800-343-9463INTRODUCTIONCustomer ServiceThank you for purchasing a WhisperKOOL Extreme Series cooling unit. We strive to provide

Page 50

www.whisperkool.com | Page 7Receiving and Inspecting the Unit • Lift only at the designated hand hold locations on the shipping container or fully su

Commentaires sur ces manuels

Pas de commentaire